Viessmann VITODENS 333-F WS3A Service Instructions Manual page 74

Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Fault
Const.
Weath.-
code
comp.
on the
display
28
X
X
30
X
X
38
X
X
40
X
48
X
50
X
X
51
X
X
58
X
X
74
System char-
Cause
acteristics
Regulates
System flow
without flow
temperature
temperature
sensor lead
sensor (low
broken
loss header)
Burner
Boiler water
blocked
temperature
sensor
shorted out
Burner
Boiler water
blocked
temperature
sensor lead
broken
Mixer closes
Heating cir-
cuit with
mixer M2
flow tem-
perature
sensor
shorted out
Mixer closes
Heating cir-
cuit with
mixer M2
flow tem-
perature
sensor lead
broken
No DHW heat-
Cylinder
ing
temperature
sensor
shorted out
No DHW heat-
Outlet tem-
ing
perature
sensor
shorted out
No DHW heat-
Cylinder
ing
temperature
sensor lead
broken
Measures
Check the low
loss header sen-
sor (see page 83)
Check the boiler
water tempera-
ture sensor (see
page 83)
Check the boiler
water tempera-
ture sensor (see
page 83)
Check flow tem-
perature sensor
Check flow tem-
perature sensor
Check sensors
(see page 83)
Check sensors
(see page 83)
Check sensors
(see page 83)