Code 2
(cont.)
Coding in the delivered condition
6F:...
Maximum output for
DHW heating in %; de-
faulted by the boiler
coding card
71:0
DHW circulation pump:
"ON" in accordance
with the DHW time pro-
gram (for Vitotrol 300,
separate switching
times are possible)
(only for weather-com-
pensated control units)
72:0
DHW circulation pump:
"ON" in accordance
with the DHW time pro-
gram (only for weather-
compensated control
units)
73:0
DHW circulation pump:
"ON" in accordance
with the DHW time pro-
gram (only for weather-
compensated control
units)
General
76:0
Without LON communi-
cation module (only for
weather-compensated
control units)
77:1
LON subscriber number
(only for weather-com-
pensated control units)
Possible change
6F:0
Max. output during DHW
to
heating adjustable from
6F:100
min. output to 100 %
71:1
"OFF" during DHW heat-
ing to the first set value
71:2
"ON" during DHW heat-
ing to the first set value
72:1
"OFF" during DHW heat-
ing to the second set
value
72:2
"ON" during DHW heat-
ing to the second set
value
73:1
During the time program
to
1x/h "ON" for 5 min
73:6
up to 6x/h "ON" for 5 min
73:7
Permanently "ON"
76:1
With LON communication
module (automatic recog-
nition)
77:2
LON subscriber number,
to
adjustable from 1 to 99:
77:99
1 - 4 = Boiler
5 = Cascade
10 - 98 = Vitotronic 200-H
99 = Vitocom
Note
Allocate each number
only once.
Coding