Troubleshooting
Fault codes
(cont.)
Fault
Const.
Weath.-
code
comp.
on the
display
9C
X
X
9F
X
X
A7
X
b0
X
X
b1
X
X
b4
X
X
b5
X
X
b7
X
X
76
System char-
Cause
acteristics
Control mode
Temperature
sensor lead
broken; con-
nects to the
Vitosolic at
S2
Control mode
Solar control
unit fault;
displayed if a
fault without
fault code
occurs at the
solar control
unit
Control mode
Faulty pro-
as per the de-
gramming
livered condi-
unit
tion
Burner
Flue gas
blocked
temperature
sensor
shorted out
Control mode
Communica-
as per the de-
tion error,
livered condi-
program-
tion
ming unit
Regulates as
Internal fault
if the outside
temperature
was 0 °C
Control mode
Internal fault
as per the de-
livered condi-
tion
Burner
Boiler coding
blocked
card fault
Measures
Check the sensor
at the Vitosolic.
Check the solar
control unit (see
solar control unit
service instruc-
tions).
Replace program-
ming unit
Check the flue
gas temperature
sensor
Check connec-
tions and replace
the programming
unit, if required
Replace the con-
trol unit
Replace the con-
trol unit
Plug in boiler cod-
ing card or re-
place, if faulty