Viessmann VITODENS 333-F WS3A Service Instructions Manual page 51

Table of Contents

Advertisement

Code 2
(cont.)
Coding in the delivered condition
91:0
No external heating pro-
gram changeover via
external extension (only
for weather-compen-
sated control units)
95:0
Without Vitocom 100
communication inter-
face
97:0
The outside tempera-
ture of the sensor con-
nected to the control
unit is utilised internally
(only for weather-com-
pensated control units)
98:1
Viessmann system
number (in conjunction
with monitoring several
systems via
Vitocom 300)
9b:0
Minimum set boiler
water temperature for
external demand
Possible change
91:1
The external heating pro-
gram changeover affects
the heating circuit without
mixer
91:2
The external heating pro-
gram changeover affects
the heating circuit with
mixer
91:3
The external heating pro-
gram changeover affects
the heating circuit without
mixer and the heating cir-
cuit with mixer
95:1
With Vitocom 100 com-
munication interface
(automatic recognition)
97:1
The outside temperature
is accepted by the LON
BUS
97:2
The outside temperature
of the sensor connected
to the control unit will be
utilised internally and is
transmitted via the LON
BUS to any connected
Vitotronic 200-H
98:1
System number adjusta-
to
ble from 1 to 5
98:5
9b:1
Minimum set boiler water
to
temperature adjustable
9b:127
from 1 to 127 °C
Coding
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents