Viessmann VITODENS 333-F WS3A Service Instructions Manual page 77

Table of Contents

Advertisement

Fault codes
(cont.)
Fault
Const.
Weath.-
code
comp.
on the
display
b8
X
X
bA
X
bC
X
bd
X
bE
X
bF
X
C2
X
X
System char-
Cause
acteristics
Burner
Flue gas
blocked
temperature
sensor lead
broken
Mixer M2 reg-
Communica-
ulates to a
tion fault, ex-
flow tempera-
tension kit
ture of 20 °C.
for heating
circuit M2
Control mode
Communica-
without remote
tion fault,
control
Vitotrol re-
mote control,
heating cir-
cuit A1
Control mode
Communica-
without remote
tion fault,
control
Vitotrol re-
mote control,
heating cir-
cuit M2
Control mode
Vitotrol re-
mote control
incorrectly
programmed
Control mode
Incorrect
LON com-
munication
module
Control mode
KM BUS
lead broken
to solar heat-
ing control
unit
Troubleshooting
Measures
Check the flue
gas temperature
sensor
Check the exten-
sion kit connec-
tions and coding.
Start the exten-
sion kit.
Check connec-
tions, cable/lead
and coding ad-
dress "A0"
Check connec-
tions, cable/lead
and coding ad-
dress "A0"
Check remote
control DIP switch
setting (see
page 105)
Replace the LON
communication
module
Check the KM
BUS cable, the
solar control unit
and coding ad-
dress "54"
77