Table 5. UNIX LLI driver messages for the Ethernet
controller (continued)
pnt0-6
pnt0-7
pnt0-11
pnt0-12
pnt0-13
pnt0-14
pnt0-15
pnt0-17
34
: Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y,
41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
Cannot allocate memory for the adapter during an
interrupt. Please check your Streams parameters.
Explanation: On a SunSoft Solaris system, this
message indicates that the system is out of Streams
memory blocks. Action: Use the CRASH utility to
increase the number of Streams memory blocks.
Modify the interrupt request (IRQ) settings in the
Configuration/Setup Utility program, or run the
NETCONFIG program to match the hardware
settings.
Cannot allocate memory for the adapter during
reset. Please check your Streams parameters.
Explanation: The system is out of Streams memory
blocks. Action: Use the CRASH utility to increase
the number of Streams memory blocks.
Device not found!
Explanation: The driver cannot find an Ethernet
controller. Action: Verify that the Ethernet controller
is enabled. If the Ethernet controller is enabled, run
the diagnostic programs.
Device failed checksum test!
Explanation: The driver cannot find an Ethernet
controller. Action: Verify that the Ethernet controller
is enabled. If the Ethernet controller is enabled, run
the diagnostic programs.
add_intr_handler failed! Interrupts already enabled.
Explanation: The interrupt request (IRQ) that was
specified, or the IRQ that was found, conflicts with
other devices in the server. Action: Modify your
hardware settings.
Cannot locate hardware.
Explanation: The SunSoft Solaris driver cannot find
any Ethernet controller. Action: Verify that the
Ethernet controller is enabled. If the Ethernet
controller is enabled, run the diagnostic programs.
No more devices to open.
Explanation: The SunSoft Solaris driver cannot find
any more Ethernet controllers. Action: Verify that
additional IBM Netfinity 10/100 Fault Tolerant
Adapters are present or replace the Ethernet
adapter that fails to respond. If the problem persists,
run the diagnostic programs.
Device fault...Reset initiated!
Explanation: The SunSoft Solaris driver has been
reset due to a device fault. Action: Verify that
additional IBM Netfinity 10/100 Fault Tolerant
Adapters are present or replace the Ethernet
adapter that fails to respond. If the problem persists,
run the diagnostic programs.