13 Technical data

13.1 DC gear motor

Operating voltage
Maximum speed
Protection class
Gear ratio
Pulse generator
Rated current

13.2 Power transformer

Operating voltage
Tolerance
Max. current draw
Fuse
Protection class
Nominal output voltage
Max. secondary current
Power filter

13.3 Controller

Operating voltage
Protection class
Control inputs
Door width
Max. counterweight
Switching capacity output relay (option)
Max. allowed storage temperature
Max. allowed operating temperature
Humidity limit
Emergency power input (option)
Recommended rechargeable battery
capacity
24 V output

13.4 Regulations and standards

EMV test
TÜV
CE
HALT test
Lift standard EN81
25
Rev.01
24 V DC
0.7 m/s
IP 54
10:1
100 impulses/revolution
4.9 A
230V, 50-60 Hz
+- 15%
2.2 A
installed by customer 10 A
IP 54
17.3V rms (full load), 23V rms (at 20mA)
15.9 A
built in
22V rms DC
IP 20
+10 V to +28 V DC, 9 to 27 mA per input
(floating, p-switched)
0.3 m to 4.00 m
6kg
230 V AC 1.0 A (at least 10 mA)
-40...+85 ° C
-20...+55 ° C
No dew point
24V +- 15%, 1.6 A (e.g. lead gel
rechargeable battery)
2 Ah, customer (!) with a 6 A slow-acting
fuse. For an opening and a closing cycle an
energy of up to 2.4 Wh is needed (0.1 Ah at
24 V)
Max. output current 400mA, short-circuit
and overload-proof
CAUTION No external voltage feed!
EN 62015 and EN 62016
Prototype tested
certified
Sample tested to 25g
from -45° C to +130° C
Conformal
Operating instructions AT18 SEDM
Issue 09/05
at temperatures
rms

Hide quick links:

Advertisement

Table of Contents
loading