11 Operating status display

The 7 segment display H5000 shows the following operating conditions:
Display
0
Signal light barrier active (light barrier interrupted)
1
RAM -, EEPROM or CPU error (system error)
2
EEPROM error
3
Error in the second power-off sequence
4
Increase of the open time with increased motor duty cycle
5
Motor undefined
6
Motor blockage in closing direction
7
Pulse generator error
8
Minimum editor is started (service button OPEN and CLOSE operated at the
same time)
9
Motor over current
A
Minimum editor (force adjustment) active
B
Reserved
C
Blockage when opening
C
Minimum editor (profile setting) active
D
Door remains standing during initialization run (no OPEN or CLOSE signal)
E
Motor over voltage
F
Motor under voltage
h
Reserved
H
Parameter determination (training run)
n
Friction values of the door too high
L
Current measurement error
o
Function O. K.
P
Parameter error (error during the training run)
u
Door is closed
U
Max. door mass exceeded
-
Controller waiting for training run