2.6.3 INTER-FUNCTION DELAY

By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254,
to match the computer response time of the keyboard interface. Such delay time is
inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the
delay time is, the slower the transmission speed will be.
Value
Delay Time
0
Disable
1 ~ 14
10 millisecond
15 ~ 24
20 millisecond
25 ~ 34
30 millisecond
35 ~ 44
40 millisecond
45 ~ 54
50 millisecond
...
...
1) Read the label above to specify the inter-function delay.
2) Read the
"Decimal
(millisecond).
3) Read the "Validate" label on the same page to complete this setting.

2.6.4 HID CHARACTER TRANSMIT MODE

By default, HID interface sends data to the host in batch. You may have the scanner read
the "By Character" label to process data one character at a time.
*Batch Processing
82
Inter-Function Delay ... (*0 ~ 254)
Value" label on page 195 for the desired inter-function delay
Value
Delay Time
195 ~ 204
200 millisecond
205 ~ 214
210 millisecond
215 ~ 224
220 millisecond
225 ~ 234
230 millisecond
235 ~ 244
240 millisecond
245 ~ 254
250 millisecond
Enter Setup
By Character