Beeper - Metapace S-2 Hardware Manual

Hide thumbs Also See for S-2:
Table of Contents

Advertisement

1.4 BEEPER

The scanner has a buzzer to provide user feedback in various operating conditions.
Beeping
One long beep, high tone
One
short
beep,
(programmable, default to 4 KHz)
Six short beeps, high-low tone
repeats three times
Two short beeps, low-high tone
One short beep, high tone
One short beep, low tone
One long beep, low tone
Two short beeps, high-low tone
Two long beeps, high-low tone
Three short beeps, tone ascending
from low to high
Three short beeps, tone ascending
from high to low
Meaning
Power on, with red LED on (1 second) and off quickly
high
tone
Good Read, with green LED on and off quickly
Enter Configuration Mode, with red LED flashing
Exit Configuration Mode
Setup label read successfully
More setup label required
Input PIN code
Clear PIN code
More barcodes required to complete the "output sequence"
requirements of Multi-Barcode Editor, with green LED on
and off quickly (Upon completion, same as Good Read.)
Transmit buffer full, with red LED on and off quickly
Transmit buffer disabled, with red LED on and off
quickly
Configuration error (Wrong label...)
PIN code input error
Reject random PIN request
Fail to send data in memory mode
Data saved to buffer when transmit buffer is enabled
and the scanner is out of range, with red LED on and off
quickly
Memory Mode – Memory full, with red LED on and off
quickly
Multi-Barcode Mode – Buffer full
WPAN connection established, with blue LED flashing
WPAN connection resumed, with blue LED flashing
WPAN connection out of range or suspended
Chapter 1
Understanding the Barcode Scanner
Update
27