Overheat Warning Indicator - Yamaha waverunner xlt800 Service Manual

Hide thumbs Also See for waverunner xlt800:
Table of Contents

Advertisement

+
ELEC
INDICATION SYSTEM

Overheat warning indicator

1. Check:
Overheat warning indicator
G
Not operating → Replace the multi-
function meter.
Checking steps:
Supply DC 12 voltage to the white
G
four-pin connector (+: red, –: black)
with a battery.
Connect the green and red terminals
G
with a jumper lead 1.
Connect the pink and black terminals
G
with a jumper lead 2.
G
Make sure the water temperature
warning indicator 3, the "
message 4 display and the "WARN-
ING" lamp 5 operate properly, and
the buzzer sounds intermittently.
7-39
E
"

Advertisement

Table of Contents
loading

Table of Contents