8.3.4.6
Service Test 6 - Open Damper Test.
When selected, this test will indicate the current position "0"/"C" (OPEN/CLOSED) of the refrigerator
damper.
• The Refrigerator Temperature Up keypad
technician must allow 1 minute for each attempt to change the damper position. The technician
should observer proper damper function.
8.3.4.7
Service Test 7 - Refrigerator Performance Adjustment.
This test will allow the service technician to adjust the control performance points. Each step will
incrementally change the refrigerator performance warmer (towards 1) or colder towards (9) as
adjusted. The default value is 5.
• The Refrigerator Temperature Up/Down keypads
Offset value. WARMER
• The last Refrigerator Performance Offset value displayed before leaving test 7 will be saved
when the refrigerator door(s) is closed.
OBSERVE DAMPER FUNCTION
(1 2 3 4 5 6 7 8 9)
DEFAULT
COLDER
61
will toggle the damper open and closed. The
/
are used to adjust the Performance
COLDER.
321023