8.1.12
Filter Status Light Reset
Once the filter light turns red, it remains red until reset. To reset the filter indicator, press both the
DISPENSER LOCK and WATER keypads simultaneously and hold for 4 seconds. Make sure the green
light flashes 3 times when the indicator resets.
8.1.13
Thermistor Resistance Chart
TEMPERATURE
O
F
70
60
50
40
30
20
10
0
-5
-10
NOMINAL OHMS
RESISTANCE
119430
157133
199016
266820
343535
445849
616353
815074
968073
1153669
49
321023