CONNECT WITH POWER SUPPLY – THE GROUND WIRE MUST BE
CONNECTED:
Use the supplied IEC lead to connect to the main power supply as follows:
Wire
Brown
Blue
Yellow /Cyan
For your safety, please kindly pay attention to all of the warnings below:
Always plug in the power plug last and disconnect from the mains when the device is
not in use or before cleaning.
Do not install and operate the device in rain or extreme heat, moisture or dusty
environments.
This device is for indoor use only and in a dry environment.
Do not switch on immediately. Wait until the unit reaches room temperature.
Do not shake the device and avoid brute force when installing or operating.
Do not use the device during thunderstorms and please disconnect the power.
Do not use solvents or aggressive detergent to clean the device. Use a soft and clean
cloth.
Do not modify the device or the connected power cord without authorisation.
Do not stare into the aperture. This product emits hazardous levels of optical radiation
and will cause serious injury to the eyes if viewed at close range.
This product should be securely mounted so that its output emission is always directed
away from people and at objects that are able to reflect emission towards people. In
this regard, the separation distances cited in HS(G)95 should be observed.
The symbol
determines the minimum distance from lighted objects. The
minimum distance between light-output and the illuminated surface must be more than
0.5m.
Connection
International signal
Live
L
Neutral
N
Earth
152.762UK User Manual

TROUBLESHOOTING

If the unit is not functioning properly
Check that the IEC cable is connected properly
Check that the mains power switch is on.
Check the fuse hasn't blown (see below guide)
Check that the unit isn't in DMX mode.
Check the safety key is turned to the on position.
If in sound to light mode ensure the microphone sensitivity is turned up.

REPLACING FUSE

First disconnect from the mains power supply then remove the fuse holder above the IEC
Socket to reveal the fuse. Replace with the correct fuse rating as stated on the product or in
the user manual. Then lock the fuse holder cover back into place.

GENERAL MAINTENANCE

Be sure to power off the fixture before conducting maintenance.
To maintain optimum performance and minimise wear, fixtures should be cleaned frequently.
Usage and environment are contributing factors in determining frequency. As a general rule,
fixtures should be cleaned at least twice a month. Dust build-up reduces light output &
performance as well as overheating. This can lead to reduced life and increased mechanical
wear.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when fixture is cold with a
mild solution to the cloth or tissue, and drag dirt and grime to the outside of the lens. Gently
polish optical surfaces until they are free of haze and lint.
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimise light output. Cleaning frequently depends on the environment in which
the fixture operates: damp, smoky or particularly dirty surroundings can require cleaning fluid.
Always dry the parts carefully. Clean the external optics at least every 20 days.