Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
56
DS_ANAB_SoftwareVersionDiagnosticsGet
1110
Get the software version of the diagnostic software of the analog board
Send command P_DS_ANACOM_SW_VERSION_DIAG with no parameters to the analog
board and read back the result
Less than 1 second
None
Number
Description
111000
Reading the diagnostics-software version succeeded
111001
The segment containing the diagnostics-software version could
not be found
111002
There was an error communicating with the analog board
111003
The analog board returned an unexpected result
DS:> 1110
111000: Diagnostics application version : 11.00.13
Test OK @
DS_ANAB_ChecksumProgram
1111
Check the checksum of the several partitions by recalculating and comparing partition
checksums
Send command P_DS_ANACOM_FLASH_CHECKSUM with no parameters to the analog
board and read back the result
Less than 5 seconds
None
Number
Description
111100
Checksum calculation succeeded
111101
The FLASH was not accessible
111102
The checksum stored in FLASH is not correct
111103
There was an error communicating with the analog board
111104
The analog board returned an unexpected result
DS:> 1111
BootCode checksum is: 0xBABE6240, which is correct
Diagnostics checksum is : 0xBABEBEAD, which is correct
Download checksum is: 0xBABEA6B7, which is correct