Yamaha DRX-2 Service Manual page 52

Hide thumbs Also See for DRX-2:
Table of Contents

Advertisement

DRX-2
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Analog Board (ANAB)
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
52
DS_DCB_Led
1006
Switch the record LED on, and after confirmation off.
The user confirms by pressing the REC key, STOP key, or the PLAY key on the local
keyboard. The PLAY key confirms that the LED is on and the REC key
-
Issue the command to light the record LED via the analog board and wait for confirmation
by the user
Until user confirmation.
None
Number
Description
100600
Switching Led on succeeded
100601
The DCB could not be accessed by the analog board.
100602
There was no response from the analog board.
100603
The DCB did not light the record LED.
100604
The user skipped the rest of the DCB_Led test.
100605
The user returned an unknown confirmation:
100606
The returned errorcode from the analog board is unknown
DS:> 1006
100600:
Test OK @
DS_ANAB_CommunicationEcho
1100
Check the communication between the digital board and the analog board by issuing some
echo string.
Send command P_DS_ANACOM_ECHO with the parameter string "Hello Analog board" to
the analog board and read back the result
Less than 1 second
None
Number
Description
110000
Communicating with the analog board succeeded
110001
The test returned the wrong string
110002
Communicating with the analog board failed
110103
The analog board returned an unexpected result
DS:> 1100
110000: Hello Analog Board
Test OK @

Advertisement

Table of Contents
loading