Yamaha DRX-2 Service Manual page 15

Hide thumbs Also See for DRX-2:
Table of Contents

Advertisement

Board overview
Fig. 6
6. You now are asked to enter an ID of the board that must
be programmed. Type a number, e.g. '6' followed by
'Enter'.
Board periphery
Fig. 7
7. Confirm the choice by typing 'y' followed by 'Enter'. Now
press any key to return to the prompt.
8. A text file called 'DBSTRING.TXT' is created, which
contains the parameters that are necessary for nucleus
1226. Copy this string from the text-file (e.g. by using
'Ctrl C').
Example of the string
Fig. 8
9. Execute nucleus 1226 with the string (paste with 'Edit'
> 'Paste to host').
Nucleus 1226 execution with string
Fig. 9
10. To check if the hardware info is filled correctly, you can
execute nucleus 1228.
Nucleus 1228 info example
Fig. 10
11. Exit the 'Terminal' program.
12. Reboot the DVD recorder to allow the software to start.
Browse to the directory with the Diagnostics software
(e.g. type 'cd c:\ds\'), and execute the 'dbstring.exe'
application.
DRX-2
15

Advertisement

Table of Contents
loading

Table of Contents