8.5

Interface data

FTB/FTC compact scales and KMB-/KMS-/KMT-TM terminals (ITB/ITS/ITT) terminals are fitted as standard with one RS232C
interface (DIN 66020; CCITT V24/V.28). They are optionally available with an additional interface (RS232, Ethernet, Digital
I/O (only KMT-TM, ITT) or analog second scale interface (KMS-/KMT-TM,ITS/ITT and FTC)).
The pins of individual interfaces are assigned as below:
5
4
3
2
1
9
8
7
6
RS232C standard interface
Pin
COM1 (RS232)
1
VCC (+5V power supply)
2
TxD 1 (transmit data)
3
RxD 1 (receive data)
4
3)
5
GND (signal ground)
6
3)
7
3)
8
3)
9
3)
2)