Summary of Contents for KERN 572

  • Page 1 KERN & Sohn GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www.kern-sohn.com Operating instructions Precision/ compact balances and platform scales KERN 572 / 573 / KB / DS / FKB Version 7.4 2017-10 572/573/KB/DS/FKB -BA-e-1774...
  • Page 2: Table Of Contents

    KERN 572 / 573 / KB / DS / FKB Version 7.4 2017-10 Operating instruction Precision/compact balances and platform scales Table of contents MODE - MENUE ....................... 4 Technical data ......................6 KERN 572 ............................. 6 KERN 573 ............................. 9 KERN KB ............................
  • Page 3 Description of the data transfer ......................37 7.5.2 Numerator ............................37 Printer ..............................37 Underfloor weighing ......................... 38 Maintenance, upkeep, disposal ................39 Cleaning ............................. 39 Maintenance, upkeep ........................39 Disposal ............................. 39 Troubleshooting ....................40 Declaration of conformity ..................40 572/573/KB/DS/FKB-BA-e-1774...
  • Page 4: Mode - Menue

    MODE - MENUE Models 572 / KB / DS / FKB non-verifiable: Important! The modified settings - as well as the adjustment - must be stored when switching-off, via the ON/OFF button. 572/573/KB/DS/FKB-BA-e-1774...
  • Page 5 Models 573-NM; KB-NM; DS-M; FKB-M: Important! The modified settings - as well as the adjustment - must be stored when switching-off, via the ON/OFF button. 572/573/KB/DS/FKB-BA-e-1774...
  • Page 6: Technical Data

    Technical data 2.1 KERN 572 KERN 572-30 572-31 572-32 572-33 Readability (d) 0,001 g 0,001 g 0,001 g 0,01 g Weighing range (max) 240 g 300 g 420 g 1.600 g Taring range (subtractive) 240 g 300 g 420 g 1.600 g...
  • Page 7 KERN 572-35 572-37 572-39 572-43 Readability (d) 0,01 g 0,01 g 0,01 g 0,1 g Weighing range (max) 2.400 g 3.000 g 4.200 g 10.000 g Taring range (subtractive) 2.400 g 3.000 g 4.200 g 10.000 g Reproducibility 0,01 g...
  • Page 8 KERN 572-45 572-49 572-55 572-57 Readability (d) 0,05 g 0,1 g 0,05 g 0,1 g Weighing range (max) 12.000 g 16.000 g 20.000 g 24.000 g Taring range (subtractive) 12.000 g 16.000 g 20.000 g 24.000 g Reproducibility 0,05 g...
  • Page 9: Kern 573

    2.2 KERN 573 KERN 573-34A 573-34NM 573-46A 573-46NM Readability (d) 0,01 g 0,01 g 0,1 g 0,1 g Weighing range (max) 650 g 650 g 6.500 g 6.500 g Taring range (subtractive) 650 g 650 g 6.500 g 6.500 g...
  • Page 10: Kern Kb

    2.3 KERN KB KERN KB 120-3N KB 240-3N KB 360-3N KB 600-2 Readability (d) 0,001 g 0,001 g 0,001 g 0,01 g Weighing range (max) 120 g 240 g 360 g 650 g Taring range (subtractive) 120 g 240 g...
  • Page 11 Weighing plate stainless 130 x 130 steel [mm] Balance 12 V, 300 mA Input voltage Power supply unit 100 V – 240V Input voltage Units see menu Net weight (kg) Interface RS232 Rechargeable battery pack 7,2 V / 2000mAh KB-A01N 572/573/KB/DS/FKB-BA-e-1774...
  • Page 12 167 x 250 x 85 Vibration filter Weighing plate stainless steel Ø 81 [mm] Balance 12 V, 300 mA Input voltage Power supply unit 100 V – 240V Input voltage Units g, kg g, kg, ct g, kg Net weight (kg) Interface RS232 572/573/KB/DS/FKB-BA-e-1774...
  • Page 13 Weighing plate stainless 150 x 170 steel [mm] Balance 12 V, 300 mA Input voltage Power supply unit 100 V – 240V Input voltage Units see menu Net weight (kg) Interface RS232 Rechargeable battery pack 7,2 V / 2000mAh KB-A01N 572/573/KB/DS/FKB-BA-e-1774...
  • Page 14: Kern Ds

    2.4 KERN DS KERN 3K0.01S 5K0.05S 8K0.05 10K0.1S Readability (d) 0,01 g 0,05 g 0,05 g 0,1 g Weighing range (max) 3.000 g 5.000 g 8.000 g 10.000 g Taring range (subtractive) 3.000 g 5.000 g 8.000 g 10.000 g...
  • Page 15 Weighing plate stainless steel 315 x 305 [mm] Balance 12 V, 300 mA Input voltage Power supply unit 100 V – 240V Input voltage Units see menu Net weight (kg) Interface RS232 Rechargeable battery pack 7,2 V / 2000mAh KB-A01N 572/573/KB/DS/FKB-BA-e-1774...
  • Page 16 Weighing plate stainless steel 450 x 350 [mm] Balance 12 V, 300 mA Input voltage Power supply unit 100 V – 240V Input voltage Units see menu Net weight (kg) Interface RS232 Rechargeable battery pack 7,2 V / 2000mAh KB-A01N 572/573/KB/DS/FKB-BA-e-1774...
  • Page 17 Weighing plate stainless steel 450 x 350 [mm] Balance 12 V, 300 mA Input voltage Power supply unit 100 V – 240V Input voltage Units see menu Net weight (kg) Interface RS232 Rechargeable battery pack 7,2 V / 2000mAh KB-A01N 572/573/KB/DS/FKB-BA-e-1774...
  • Page 18: Kern Fkb

    2.5 KERN FKB KERN 6K0.02 8K0.05 16K0.05 16K0.1 Readability (d) 0,02 g 0,05 g 0,05 g 0,1 g Weighing range (max) 6.000 g 8.000 g 16.000 g 16.000 g Taring range (subtractive) 6.000 g 8.000 g 16.000 g 16.000 g...
  • Page 19 Weighing plate stainless steel 340 x 240 [mm] Balance 12 V, 300 mA Input voltage Power supply unit 100 V – 240V Input voltage Units see menu Net weight (kg) Interface RS232 Battery operation 6 x 1,5 V; Size C 572/573/KB/DS/FKB-BA-e-1774...
  • Page 20 Weighing plate stainless steel 340 x 240 [mm] Balance 12 V, 300 mA Input voltage Power supply unit 100 V – 240V Input voltage Units see menu Net weight (kg) Interface RS232 Battery operation 6 x 1,5 V; Size C 572/573/KB/DS/FKB-BA-e-1774...
  • Page 21: Fundamental Information (General)

    Information is available on KERN’s home page (www.kern-sohn.com) with regard to the monitoring of balance test substances and the test weights required for this. Test weights and balances can be adjusted quickly and at a reasonable price in KERN’s ac- credited DKD calibration laboratory (return to national normal).
  • Page 22: Fundamental Safety Information

    4.1 Observe the information in the operating instructions Carefully read this operation manual before setup and com- missioning, even if you are already familiar with KERN balanc- Versions in other languages are non-binding translations. The only binding version is the original document in German.
  • Page 23: Unpacking, Installation And Commissioning

    Electric power supply is by means of the external mains supply circuit. The printed voltage level must comply with the local voltage. Only use original KERN mains supply circuits. The use of other makes is subject to ap- proval by Kern.
  • Page 24: Battery Operation Fkb

    The balance must be disconnected from the mains before connecting or disconnecting additional equipment (printer, PC) to or from the data interface. Only use KERN accessories and peripheral equipment with your balance. These have been ideally coordinated to your balance.
  • Page 25: Adjusting (Go To 7.2.6)

    Check that the surrounding conditions are stable. A short warm-up time of about 15 minutes is recommended for stabilisation. 6.8.1 Adjusting for verification (KERN 573; FKB-M; KB-NM; DS-M) General Information: Prior to the procedure of verification the balance has to be adjusted.
  • Page 26: Verification

    The weighing result of the balance is outside the error limit. Therefore, in reg- • ular intervals load balance with known test weight (ca. 1/3 of the max. load) and compare with displayed value. The reverification deadline has been exceeded. • 572/573/KB/DS/FKB-BA-e-1774...
  • Page 27: Operation

    % and counting mode: Form reference in MODE: Yes / ascending MODE configuration (see mode structure diagram page 2) Formula weighing in MODE: to left Change g-pieces Unit changeover in MODE: to right Tare in MODE: back in weighing operation 572/573/KB/DS/FKB-BA-e-1774...
  • Page 28 Gross weight of several components during formula preparation Balance is in counting mode and currently displaying the weight value of the count-  ing amount For multirange balance in verification operation indication of range III. Warm-up time if verifiable (switch-on drift monitoring) Wait > 299 s 572/573/KB/DS/FKB-BA-e-1774...
  • Page 29: Operation

    7.2 Operation 7.2.1 Weighing with Tare 7.2.2 Count – Selection reference piece 7.2.3 Percent % 7.2.4 Formula Weighing 7.2.5 Tolerance Weighing 572/573/KB/DS/FKB-BA-e-1774...
  • Page 30 572/573/KB/DS/FKB-BA-e-1774...
  • Page 31: Adjust

    7.2.6 Adjust 7.2.7 Preselect Tare 7.2.8 Auto Tare active 7.2.9 Filter / Speed 7.2.10 Auto Off active 7.2.11 Variable Factor 7.2.12 Preselect Unit 572/573/KB/DS/FKB-BA-e-1774...
  • Page 32 572/573/KB/DS/FKB-BA-e-1774...
  • Page 33: Animal Weighing

     Printing and deleting of the average value can be triggered by the PRINT key  Simple deleting is possible by pressing the TARE key.  7.2.14 Swap:  Strong filtering 572/573/KB/DS/FKB-BA-e-1774...
  • Page 34 Var 1 Col 14 Var 5 Type xx = Pcs / % Printout “Gross“ line 2 / column 14 Var 6 Type xx = * / Mw xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 1. line xxxxxxxxxxxxxG 15000.0g xxxxxx 2. line Var 7 Type xx = Numerator 572/573/KB/DS/FKB-BA-e-1774...
  • Page 35: Display Background Illumination

     Baud rate adjustable to 2400, 4800 and 9600 baud (default), 19200 baud  Sup-D- 9 pol. is necessary .  When working with an interface correct operation is secured only if the corresponding KERN-interface-cable (max. 2m) is used. Description of the jack Sup-D- 9 pol.
  • Page 36: Rs 232 C Data Output Via Interface Rs 232 C

    The printer format is stored in the printer, i.e. in case of a failure the printer cannot be changed with a new one from factory, previously it is necessary that KERN installs the re- spective software. The Zebra printer and the balance must be connected to the delivered interface cable when they are switched off.
  • Page 37: Description Of The Data Transfer

    When the percent mode is selected, the percentage or the weight will be printed. Press The PRINT-key to print weighing results. Select the enu- merator to number the weighing continuously. Turn off the balance or use the CLEAR function to Reset the enumerator to (000). 572/573/KB/DS/FKB-BA-e-1774...
  • Page 38: Underfloor Weighing

    Always make sure that there are no living beings or materials below the load that could be injured or damaged. ! NOTE ! After completing the underfloor weighing, the opening in the floor of the balance must be closed again (dust protection). 572/573/KB/DS/FKB-BA-e-1774...
  • Page 39: Maintenance, Upkeep, Disposal

    Remove any spilt material to be weighed immediately. 8.2 Maintenance, upkeep The device may only be opened by trained service engineers authorised by KERN. Disconnect from the mains supply before opening. 8.3 Disposal The operating company shall dispose of the packaging and the device in compliance with the valid national or regional law of the operating location.
  • Page 40: Troubleshooting

    Contact the manufacturer if the error message does not disappear. Declaration of conformity To view the current EC/EU Declaration of Conformity go to: www.kern-sohn.com/ce The scope of delivery for verified weighing balances (= conformity- rated weighing balances) includes a Declaration of Conformity. 572/573/KB/DS/FKB-BA-e-1774...