Technical Specifications

Item
Height x Width x Depth
Weight
Power
Class 2 Transformer normal
service input voltage range
Approvals
FCC Part 15
Safety Certifications
Physical Environment
Operating temperature
Storage temperature
Relative humidity
Shock and vibration
Heat Dissipation
Interface Connectors
Line and Phone Interfaces
Ethernet Type II Frame
REN Support
*
Technical Specifications subject to change without notification.

Technical Support

For assistance installing or configuring your SuperLine Adapter, contact your local
telephone company.
Trademarks
All products and services mentioned herein are the trademarks, service marks,
registered trademarks or registered service marks of their respective owners.
*6512-A2-GN10-10*
Copyright E 1999 Paradyne Corporation
*
Specification
2.19 x 7.60 x 12.132
(5.56 cm x 19.30 cm x 30.82 cm)
2 lb. 2 oz.
Input:
120 Vac (+10%), 60 Hz
Output:
18 Vdc nominal at 0.6A
Class B digital device
Refer to equipment's label for approvals on product.
32 F to 104 F ( 0 C to 40 C )
– 4 F to 158 F ( –20 C to 70 C )
5% to 95% ( noncondensing )
Withstands normal shipping and handling
22.2 Btu/hr. (max.) at nominal input voltage
RJ11/RJ14 6-pin
10BaseT 8-pin
Provides adequate ringing signals for a total REN of 3
on each SuperLine port (PHONE 1/2 or PHONE 2)
*6512–A2–GN10–20*