12
Test block 2 – outputs
.14.03
Output number
●
The current output is displayed with the +/- key B.
●
Press the +/- key B to display the other outputs.
●
If the +/- key D is pressed, the output is switched on for 200 ms
12
Test block 3 – Set value sender and actual value sender
.14.04
Set value sender
●
All 16 switch positions can be called up by operating the pedal. If all positions from -2, -1,
0, 1, 1D to 12D appear on the display, the set value sender is in order.
●
The actual value can be checked by turning the balance wheel. If all increments from
0 - 255 appear on the display, the actual value sender is in order.
A
1
0
X5:
28
Connector
Output status
If the D+ key is pressed, the output is
switched on for 200 ms
SWG
-2
x
IWG
Pedal setting
Contact number
Adjustment