The Basic menu

Accessing the
Basic Menu
The Basic menu is displayed.
7
8
9
Basic Menu En-
The Basic menu contains the following parameters important for the installation and op-
tries
eration of the inverter:
MPP Tracker 1
-
-
-
-
A c c e s s C o d e
Use the 'plus' or 'minus' keys
Press the 'Enter' key
Press the 'Esc' key
DC operating mode: MPP AUTO / FIX / MPP USER
-
MPP AUTO: normal operating status; the inverter automatically searches for the
optimal operating point
-
FIX: enter a fixed DC voltage used by the inverter. Enter the fixed voltage value
in the fixed voltage point.
-
MPP USER: enter the lower MPP voltage from which the inverter searches for
its optimal operating point. Enter this start value for the MPPT start voltage.
Dynamic Peak Manager: ON/OFF
Fixed voltage: enter the fixed voltage for the FIX function
MPPT start voltage: enter the start voltage for the MPP USER function
Press the 'Menu' key
1
The menu level is displayed.
Press the unassigned 'Menu/Esc' key
2
5 times
In the "CODE" menu, the "Access Code" is dis-
played; the first digit flashes.
Enter code 22742: Use the 'plus' or 'minus'
3
keys
to select the first digit of the code
Press the 'Enter' key
4
The second digit flashes.
Repeat steps 3 and 4 for the second, third,
5
fourth, and fifth digit of the code until...
the set code flashes.
Press the 'Enter' key
6
to select the desired entry
to edit the selected entry
49