Minolta Dimage Scan Multi2 User Manual page 90

Image scanner
Table of Contents

Advertisement

SETTING THE PREFERENCES
Multi Sample
This option allows you to select the Multi-Sampling setting. This function reduces the random
noise of image by analyzing the data of sampling exposure in advance. Select one from the
following items of the list box.
The Multi-Sample Scanning function is turned off in the default setting.
OFF
Not use the Multi-Sample Scanning function.
2 times
Perform the sampling 2 times.
4 times
Perform the sampling 4 times.
8 times
Perform the sampling 8 times.
16 times
Perform the sampling 16 times.
* The more the times of performing the sampling are, the longer the required time of scanning
is.
Index Scan Priority
This option allows you to select either a high speed index scan or a quality index scan by
clicking on "Speed" or "Quality".The default setting is "Speed".
Speed This performs the index scan at high speed. The autofocus function is not used
while scanning. The index images are displayed in a thumbnail representation after
only easy-auto expose function is performed for each frame.
Quality After prescanning each frame, the size of the prescan images is reduced and those
images are displayed in the thumbnail representation. Therefore, it takes much time
to display index images. However, the prescan image can be immediately displayed
just by double-clicking the index image. Whether to perform the autofocus function
or the auto expose function for a color slide film when prescanning depends on the
setting of Auto Focus at Scan or Auto Exposure for Slides.
Color Matching
When displaying the scanned image in the monitor of the PC, the color of the image varies
depending on the type of the monitor. This option allows you to match the color data of the
scanned image to the monitor specifications.
For details, see page 92.
– 90 –

Advertisement

Table of Contents
loading

Table of Contents