1. Remove center terminal block screw.
2.
Remove neutral grounding wire (green with yellow stripes)
from external ground conductor screw. Fasten it under center,
silver-colored
terminal block screw.
A.
External ground conductor
position of NEUTRAL grounding
moved to center terminal block screw
B. ~nter
silver-colored
C.
Green/yellow
wire of harness
3.
Connect ground wire (green or bare) of power supply cord to
external ground conductor
4.
Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block.
A Extemal ground conductor
B, Ground wire (green or bare) of power supply cord
C. ~. (1.9 cm) UL listed strain relief
D. ~nter
silver-colored
E. Neutral grounding
F. Neutral wire (white or center wire)
5. Connect the other wires to outer terminal block screws.
Tighten screws.
6. Tighten strain relief screws.
7.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
8
c
screw - Dotted fine shows
wire before being
terminal block
SCf9W
screw. TIghten screw.
screw
terminal blocJc screw
wire (green with yellow stripes)
4-wire connection: Direct wire
IMPORTANT: A 4-wire connection
and where local codes do not perm~ the use of 3-wire
connections.
Direct wire cable must have 5 It (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5' (12.7 em) of outer covering from end of cable. leaving
(12.7
bare ground wire at 5'
3 remaining wires. Strip insulation back l' (2.5 em). Shape ends
of wires into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example
below.
1. Remove center terminal block screw.
2.
Remove neutral grounding wire (green with yellow stripes)
from external ground conductor screw. Fasten it under cente"
silver-colored terminal block screw.
A.
External ground conductor
posffion of NEUTRAL grounding
moved to center terminal block screw
B.
Center sifver-<:olored terminal block screw
C.
Green/yellow
wire of harness
is required for mobile homes
1'1z"
em). Cut
(3.8 em) from
8
screw - Dotted line shows
wire before being

Hide quick links: