5.3.6 MOUNT VALVES
The follwing procedure must be applied to all the valves and
relative components.
Oil the valve stem with the recommended oil.
RECOMMENED OIL
Disulfide of molybdenum oil
Mount the lower small cup (1).
Check the thickness of the small cup. If the thickness is 1.5
mm add a clearance adjustment of 0.6 mm.
WARNING:
Always use new gaskets and oil seals.
Mount the valve holder hood (2) with the apposite pad (3).
SPECIFIC EQUIPMENT
INSTRUMENT (3): R180197025000
UK