Section 3: Operation
3-52 Christie DS+60/DW30/Matrix 3000 User's Manual
NOTES: 1) The projector will automatically shutdown if it detects both lamps
have "failed" (this includes lamps not installed). 2) The lamp operation mode
will not automatically switch to a previous mode once a "failed" lamp is
replaced. It must manually be selected. 3) It takes approximately 25 seconds
for a cold lamp to reach full brightness when it is first turned on. 4) Power is
cut to a lamp only when the lamp operation mode is switched to the other
lamp. IMPORTANT - the original lamp stays on for 35 seconds to allow the
new lamp to warm up before power is cut and lamp operation modes change.
MORE LAMP 1 (MORE LAMP 2) -
accessed from the Lamp menu. Each submenu is dedicated to one lamp – you can
view specific lamp information, such as lamp hours, lamp history and the current
status of the lamp. You can also change lamp operation modes.
- This read-only information shows the current number of hours
LAMP HOURS
logged on the current lamp. Whenever a new lamp serial number is detected it begins
to log time for the new lamp. This information also appears in the Status menu.
- This read-only information displays the serial number for the current
LAMP S/N
lamp. NOTE: When a lamp is installed, the projector automatically detects the serial
number and displays it here. The serial number is not manually entered.
– This read-only information displays the current status of a
LAMP 1 (OR 2) STATUS
lamp and can be viewed any time during operation. Refer to the list below for the
possible lamp status messages and their meaning:
continually appears as the status until there is a failure with one of the
"Good"
lamps. Then one of the other error messages will display.
"Failed to Strike"
may or may not be lamp related. Further investigation is required.
"Lamp Not Installed"
check to ensure the lamp is fully inserted and connected to the terminal block.
"Turned Off Unexpectedly"
component, such as a lamp driver fails. Check for an error code on the status
display.
"Interlock Tripped"
is still on. In this case, the lamp will automatically be turned off.
"Cooling Fan #8 (or #10) Failed"
lamp fans fail. (Cooling fan #8 is associated with Lamp #1 and Cooling fan
#10 with Lamp #2)
"Color Wheel Stopped"
"Operation Error"
and the lamp is off. This typically occurs when trying to turn on a hot lamp.
"Driver Vcc too Low"
This read-only option lists the lamp serial
LAMP HISTORY -
number and corresponding lamp hours of the lamp most recently
installed. Lamp History is automatically updated when a new
lamp is installed.
There are two separate lamp submenus that can be
will display when the projector fails to turn a lamp on. This
will display when a lamp is not detected. If present,
will display when a lamp or lamp related
will display when the lamp door is opened for a lamp that
will display when one of the corresponding
will display when a color wheels ceases operation.
will display when the lamp driver reports an operation error
will display when a lamp driver fails.