6 - 2
Purpose
Operation test/check
Function
Used to check the operation of each fan motor and its
(Purpose)
control circuit.
Section
Others
Item
Operation
Operation/
1. The names of the loads which can be operated are
Procedure
displayed.
Select the load to be checked with the key, and the
selected load is highlighted.
2. Press the [EXECUTE] key.
The key is highlighted and the selected fan motor is rotated.
If the [EXECUTE] key is pressed while the fan motor is rotating,
the [EXECUTE] key returns to the normal display and the fan mo-
tor is stopped. To operate or stop each fan motor, press the key of
the fan motor.
However, [CFM Low] key and [CFM High] key cannot be pressed
ON simultaneously.
7
7 - 1
Purpose
Setting/Operation test/check
Function
Used to set the aging operation conditions.
(Purpose)
Item
Operation
Operation/
1. Press each corresponding key to set for the aging
Procedure
operation.
(Set items of each key)
[AGING]
Aging setting
[MISFEED DISABLE]
Jam detection enable/disable setting
[FUSING DISABLE]
Fusing operation enable/disable setting
[WARMUP DISABLE]
Warm-up save setting
[INTERVAL]
Intermittent setting (Valid only in [AGING]
setting)
[DV CHECK DISABLE] Developing unit detection enable/disable
setting
[SHADING DISABLE]
Shading enable/disable setting
The selected key is highlighted.
2. Press the [EXECUTE] key.
Aging is set and the display returns to the simulation main code
entry display.
*
When this simulation is executed, the machine resumes operation
regardless of setting (changing) of aging.
7 - 6
Purpose
Setting/Operation test/check
Function
Used to set the cycle of intermittent aging.
(Purpose)
Item
Operation
Operation/
1. Enter the interval aging cycle time (sec) with the 10-
Procedure
key pad.
2. Press [OK] key to set the entered cycle time.
7 - 8
Purpose
Setting/Operation test/check
Function
Used to set YES/NO of display of the warmup time.
(Purpose)
Item
Operation
Operation/
Press the [EXECUTE] key to set the warmup time dis-
Procedure
play.
When the [EXECUTE] key is pressed, the warmup time
display setting is executed and the display returns to
the simulation main code entry display.
*
When this simulation is canceled after completion of it, the machine
resumes operation regardless of setting (changing) of warmup time
display.
7 – 14