6 Commissioning

Slide the switch until the "I" symbol
appears.
The operating indicator on the control
panel turns on: the boiler is ready to
operate.
Open the isolating valves located on
the pipes: they will be placed in the
direction of the flow.
Open the auto air vent on the pump as
well as the automatic bleeders of the
system.
Open the blue filling loop valve situated
under the boiler until you obtain a 2
bars pressure on the indicator.
Bleed each radiator to remove the air,
re-tighten bleed screws.
Leave the cap on the pump auto air
vent open.
Flush the domestic hot water system by
openning the hot water taps for several
minutes.
Make sure the display indicates a
system pressure of between 1 and 2
bars. Re-fill system as necessary.
7 Specific adjustments
7.1
Heating circuit adjustment
This flow rate will be adjusted according to
the system calculations.
When it is delivered, the (1) integrated
bypass screw is open by half a turn.
Legend
1
Bypass screw
Depending on the requirements, adjust
this screw (for example, screw for
closing) in order to fit the available
pressure head to the system energy
loss according to the output/pressure
curve.
1
2
3
4
Legend
1
Speed III
2
Speed II
3
Speed I
4
Speed selector of pump
Turn the selector (4) to choose pump
speed I, II or III in relation to the output/
pressure curve.
30