Inspect the burner for any signs of
damage.
Inspect the sealing rings and replace if
necessary.
Removal of the burner is not necessary
during a normal service.
14.5.3
Heat exchanger
Remove the 2 mixing arm retaining
screws (23) bolted on the fan (33).
Remove the 5 heat exchanger retaining
nuts (17).
Remove the "burner + mixing arm" unit
from the heat exchanger.
Remove loose debris from combustion
chamber using a soft brush and
vacuum cleaner. Carefully flush by
spraying water removing any remaining
debris through the condensate trap
(Ensure the water is kept away from
electrical components).
14.5.4
Combustion Check.
If a gas carrying component has
been replaced, the combustion of the
appliance should be checked.
Once the appliance has been re-
assembled (apart from the front and
inner casing panels) connect a CO2
combustion analyser to the test point
on the flue adapter (see chapter «Gas
conversion»).