5.1.4 Water treatment
In the case of an existing installation, it is
Essential that prior to installing the new
boiler the system is thoroughly flushed.
For optimum performance after
installation of a new system, the boiler and
its associated central heating system
should also be flushed.
Flushing should be carried out in
accordance with BS7593: 1992 using a
cleanser such as Sentinel X300 or X400,
Fernox Superfloc or Salamander corrosion
guard cleaner.
For long-term corrosion protection, after
flushing, an inhibitor suitable for stainless
steel heat exchangers should be used,
refer to the current issue of BS 5449 and
BS 7593 on the use of inhibitors in central
heating systems. Examples are Sentinel
X100 Fernox or Salamander corrosion
guard inhibitor.
5.2

Dimensions

3 0 1
8 9 0
7 0 0
5.3
List of delivered equipment
The boiler is delivered in two packages:
-
The boiler and the hanging bracket.
-
One documentation pack:
- 1 user and installation manual
- 1 guarantee envelope
- 1 Wiring diagram
- 1 gasket pack
One parts pack:
- 1 connection pack 1
- 1 connection pack 2 + wall template
- 1 safety valves drain pack
The flue is supplied separately and will
depend upon the configuration of the
installation.
5.4
Fixing to the wall
Make sure the material you use fits
those of the appliance.
Chose the location of the appliance.
See chapter "Appliance location".