Condensate Trap - Saunier Duval ISOTWIN CONDENS F 35 E Instructions For Use, Installation & Servicing

High efficiency condensing combination boiler
Table of Contents

Advertisement

15.4 Condensate trap

1
2
3
4
5
Legend
1
Flexibles
2
Float
3
Condensate trap retaining screw
4
Condensate trap
5
Draining flexible
6
Siphon adapter
Disconnect the connector flexible (5)
located under the condensate trap.
Remove the front face of the tight
chamber.
Loosen both retaining screw (3) of the
condensate trap (4).
Remove the condensates recovery
equipment by loosening flexibles (1);
take care do not spray liquid.
Warning: condensate is acidic: use
protective gloves.
Fit the new condenstae trap in the
reverse order.
15.5 Control panel
15.5.1
Access to the printed circuit
6
board
1
2
Legend
1
Switchbox protective cover retaining
screw
2
Cover retaining plate on the switchbox
Remove the 2 switchbox protective
cover retaining screws (1).
Remove the cover retaining plate on
the switchbox (2).
Remove the switchbox protective cover.
52

Hide quick links: