Hydraulic System

The hydraulic units are aoi- and mainte-
nance-free. The hydraulic oil and filter
concerned my maintenance work only.
Premature failure can be prevented by
regular inspection and periodical main-
tenance according to maintenance
schedule.
We recommend having all oth-
er works at the hydraulic sys-
tem done by a authorized
Hako-service-workshop.
5.11.1 Check Hydraulic
Fluid Level
• Turn engine off and pull key.
• Secure machine by engaging park-
ing brake.
• Open quick-release locks (Fig. 22/1)
and remove cover (Fig. 22/2)
• Clean the area of the dipstick (Fig.
22/3).
• Pull dipstick (Fig. 22/3).
• Wipe dipstick by means of cloth.
• Put in dipstick until stop.
56
Fig.22
2
1
1
Max
Min
3
3