Dismount Plate Filter - HAKO Sweepmaster P1200 RH Instruction Manual

Hide thumbs Also See for Sweepmaster P1200 RH:
Table of Contents

Advertisement

Maintenance and Care
5.8

Dismount Plate Filter

Proceed as follows for dismounting of
the plate filter:
• Turn engine off and pull key.
• Secure machine by engaging park-
ing brake.
• Open quick-release locks (Fig. 15/1)
and remove cover (Fig. 15/2).
• Remove cover (Fig. 15/3) of the filter
installation.
• Loosen wing screws, four peaces,
(Fig. 15/4) and remove.
• Fold back frame (Fig. 15/5) and hook
frame (Fig. 15/5) at indicated posi-
tion by rubber fastening (Fig. 15/6).
• Remove plate filter (Fig. 15/7).
For mounting of plate filter proceed in
inverse order.
Clean filter area.
Check plate filter of damaging.
Watch for direction of the air on
the plate filter.
Check for correct fit of the plate
filter in the machine frame.
4
5
Fig.15
2