Toshiba RAV-SM564UT-E Service Manual page 85

Hide thumbs Also See for RAV-SM564UT-E:
Table of Contents

Advertisement

2) Heating fan control

The outdoor fan is controlled by TE sensor, TO sensor and the operation frequency.
(From Min. W1 to Max. are controlled according to the following table.)
During 3 minutes after start-up, the fan is fixed
with the maximum fan tap corresponding to zone
in the following table.
After then the fan is controlled by temperature of
TE sensor.
ƒ
If status, TE > 24°C continues for 5 minutes, the
operation stops.
This status is same to the usual Thermo-OFF
which has no alarm display, and the fan restarts
after 2 minutes and 30 seconds.
This intermittent operation is not abnormal.
When the above status
considered that the filter of suction part of the
indoor unit is stain.
Clean the filter and then restart the operation.
10°C ≤ TO
Maximum
5. Coil heating control
1) This control function heats the compressor by turning on the stopped compressor instead of a case heater.
It purposes to prevent slackness of the refrigerant inside of the compressor.
2) As usual, turn on power of the compressor for the specified time before a test run after installation,
otherwise a trouble of the compressor may be caused.
As same as a test run, it is recommended to turn on power of the compressor beforehand when starting
operation after power of the compressor has been interrupted for a long time.
3) Coil heating is controlled by TD and TE sensor.
4) The power is turned off when TD is 30°C or more.
TE [˚C]
0
–1
–6
–7
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
occurs frequently, it is
Temp. range
5 ≤ TO < 10°C
–5 ≤ TO < 5°C
TO < –5°C
TO error
No power-ON
Continuous ON (L)
Continuous ON (H)
– 85 –
www.heronhill.co.uk
TE [˚C]
24
21
18
15
38.9Hz ≤ ≤ ≤ ≤ ≤ f < 67.6Hz
f < 38.9Hz
W7
W8
WA
WB
WE
WF
WE
WF
WE
WF
L
H
–2 tap/20 seconds
STOP timer count
–2 tap/20 seconds
–1 tap/20 seconds
rpm hold
+1 tap/20 seconds
67.6Hz ≤ ≤ ≤ ≤ ≤ f
W9
WD
WF
WF
WF
SP40, SP45
10W and equivalent
30W and equivalent
Fax: 01823 665807

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents