Toshiba RAV-SM564UT-E Service Manual page 11

Hide thumbs Also See for RAV-SM564UT-E:
Table of Contents

Advertisement

<Twin type>
Indoor unit 1
Model
Indoor unit 2
Outdoor unit
Cooling capacity
Heating capacity
Power supply
Cooling
Electrical
characteristics
Heating
Fan
Fan unit
Standard air flow H/M/L
Motor
Sound pressure level
Sound power level
Power supply
Standard length
Min. length
Max. total length
Refrigerant
pipe
Refrigerant charging amount
(Charge-less up to 30m)
Height
difference
Fan
Fan unit
Standard air flow volume
Motor
Gas side
Connecting
pipe
Liquid side
Sound pressure level
Sound power level
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
Indoor unit
Running current
Power consumption
Power factor
EER
Energy efficiency class ∗
Running current
Power consumption
Power factor
COP
Energy efficiency class ∗
(m³/min.)
H/M/L
(dB•A)
H/M/L
(dB•A)
Outdoor unit
Outdoor lower
Outdoor higher
(m³/min.)
Main
Sub
Main
Sub
Cooling/Heating
(dB•A)
Cooling/Heating
(dB•A)
– 11 –
www.heronhill.co.uk
RAV-
SM564UT-E
RAV-
SM564UT-E
RAV-
SP1104AT(Z)(ZG)-E
(kW)
10.0
(kW)
11.2
1 phase 230V (220 – 240V) 50Hz
(A)
10.36 – 9.49
(kW)
2.21
(%)
97
4.52
A
(A)
10.96 – 10.05
(kW)
2.34
(%)
97
4.79
A
17.5 / 14.5 / 13.0
(W)
14
32 / 29 / 28
47 / 44 / 43
1 phase 230V (220 – 240V) 50Hz
(m)
7.5
(m)
3
(m)
50
40g/m (31m to 50m)
(m)
30
(m)
30
101
(W)
100 + 100
(mm)
15.9
(mm)
12.7
(mm)
9.5
(mm)
6.4
49 / 50
66 / 67
Revised 2: Jun., 2008
SM804UT-E
SM804UT-E
SP1404AT(Z)(ZG)-E
12.5
14.0
14.66 – 13.44
3.16
98
3.96
A
14.89 – 13.65
3.21
98
4.36
A
Turbo fan
20.5 / 16.0 / 13.5
20
35 / 31 / 28
50 / 46 / 43
7.5
3
50
30
30
Propeller fan
103
100 + 100
15.9
15.9
9.5
9.5
51 / 52
68 / 69
∗ : IEC standard
Fax: 01823 665807

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents