Mitsubishi Electric 700 Series Programming Manual page 60

700 series plc function programming manual
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

2.3.4
I/O signal when CC-Link Ver.2 octuple setting is selected
(Pr. 544 = 118)
The device points usable in CC-Link communication are 32 input (RX) points (12
points are available for PLC function), 32 output (RY) points (12 points are available
for PLC function), 16 remote register (RWr) points and 16 remote register (RWw)
points.
(1) Remote I/O
Same as when Pr. 544 = 112 (
(2) Remote resister
PLC function
Address
device No.
RWwn
RWwn+1
RWwn+2
RWwn+3
RWwn+4
RWwn+5
RWwn+6
RWwn+7
RWwn+8
RWwn+9
RWwn+A
RWwn+B
RWwn+C
RWwn+D
RWwn+E
RWwn+F
*1
When Pr. 128 = "50, 51, 60, 61", they are valid.
Refer to page 52)
Description
Upper 8
Lower 8
Bits
Bits
Monitor
Monitor
code 2
code 1
Set frequency
(0.01Hz increments)
Link
Instruction
parameter
code
expansion
setting
Write data
Monitor code 3
Monitor code 4
Monitor code 5
Monitor code 6
Alarm
definition
H00
No.
PID set point
(0.01% increments) *1
PID measured value
(0.01% increments) *1
PID deviation
(0.01% increments) *1
toruqe command / limit
(0.01% increments)
H00 (Free)
CC-Link I/O Specifications
PLC function
Address
device No.
RWrn
RWrn+1
RWrn+2
RWrn+3
RWrn+4
RWrn+5
RWrn+6
RWrn+7
RWrn+8
RWrn+9
RWrn+A
RWrn+B
RWrn+C
RWrn+D
RWrn+E
RWrn+F
Description
First monitor value
Second monitor
value
Reply
Reply
code2
code1
Read data
Third monitor value
Fourth monitor value
Fifth monitor value
Sixth monitor value
Alarm
Alarm
definition
definition
No.
data
Alarm definition
(output frequency)
Alarm definition
(output current)
Alarm definition
(output voltage)
Alarm definition
(energization time)
H00 (Free)
55
2