(1) Performs the division of BIN data specified at
, and stores the result into the device specified at
S2
(2) In regards to the operation result, the quotient and remainder are stored by use of
32 bits in the case of word device, and only the quotient is stored by use of 16 bits
in the case of bit device.
Quotient :
Remainder :
(3) At
and
S2
S1
(4) The judgment of whether the data of
negative is made at the highest bit (b15).
(Both quotient and remainder have sign.)
0 ...... Positive
1 ...... Negative
Execution Conditions
The execution conditions of the transfer instructions are as shown below.
Multiplication/division
command
Stored to the lower 16 bits.
Stored to the upper 16 bits. (Storable only in the case of word
device)
, -32768 to 32767 (BIN 16 bits) can be specified.
and the BIN data specified at
S1
D
Quotient
,
,
and
S1 S2
D
Executed every
scan.
Executed only once.
Basic Instructions
.
Remainder
+1 are positive or
D
Executed every
scan.
Executed only once.
3
151