Mitsubishi Electric 700 Series Programming Manual page 57

700 series plc function programming manual
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

CC-Link I/O Specifications
2.3.2
I/O signal when CC-Link Ver.2 double setting is selected
(Pr. 544 = 112)
The device points usable in CC-Link communication are 32 input (RX) points (12
points are available for PLC function), 32 output (RY) points (12 points are available
for PLC function), 4 remote register (RWr) points and 4 remote register (RWw) points.
(1) Remote I/O
Remote
PLC
output
function
device
device
No.
No.
X30
RYn0
Forward rotation command
X31
RYn1
Reverse rotation command
High-speed operation
X32
RYn2
command
(terminal RH function) *1
Middle-speed operation
X33
RYn3
command
(terminal RM function) *1
Low-speed operation
X34
RYn4
command
(terminal RL function) *1
Jog operation command
X35
RYn5
(terminal JOG function) *1
Second function selection
X36
RYn6
(terminal RT function) *1
Current input selection
X37
RYn7
(terminal AU function) *1
Selection of automatic restart after
X38
RYn8
instantaneous power failure
(terminal CS function) *1
X39
RYn9
Output stop
Start self-holding selection
X3A
RYnA
(terminal STOP function) *1
Reset
X3B
RYnB
(terminal RES function) *1
RYnC
Monitor command
Frequency setting command
RYnD
(RAM)
Frequency setting command
RYnE
(RAM, EEPROM)
Instruction code execution
RYnF
request
RY(n+1)0
Reserved
to
RY(n+1)7
Not used
(initial data process
RY(n+1)8
completion flag)
Not used
(initial data process request
RY(n+1)9
flag)
Error reset request flag
RY(n+1)A
RY(n+1)B
Reserved
to
RY(n+1)F
52
Signal
Remote
PLC
input
function
device
device
No.
No.
X30
RXn0
Forward running
X31
RXn1
Reverse running
Running
X32
RXn2
(terminal RUN function) *2
Up to frequency
X33
RXn3
(terminal SU function) *2
Overload alarm
X34
RXn4
(terminal OL function) *2
Instantaneous power failure
X35
RXn5
(terminal IPF function) *2
Frequency detection
X36
RXn6
(terminal FU function) *2
Error
X37
RXn7
(terminal ABC1 function) *2
 (terminal ABC2 function) *2
X38
RXn8
Pr. 313 assignment function
X39
RXn9
(DO0)
Pr. 314 assignment function
X3A
RXnA
(DO1)
Pr. 315 assignment function
X3B
RXnB
(DO2)
RXnC
Monitoring
Frequency setting completion
RXnD
(RAM)
Frequency setting completion
RXnE
(RAM, EEPROM)
Instruction code execution
RXnF
completion
RX(n+1)0
Reserved
to
RX(n+1)7
Not used
(initial data process request
RX(n+1)8
flag)
Not used
(initial data process
RX(n+1)9
completion flag)
Error status flag
RX(n+1)A
Remote station Ready
RX(n+1)B
RX(n+1)C
Reserved
to
RX(n+1)F
Signal

Hide quick links: