Mitsubishi FX2N User Manual page 67

Profibus-dp interface unit
Hide thumbs Also See for FX2N:
Table of Contents

Advertisement

FX2N-32DP-IF Profibus-DP Interface Units
2) Step 2 of returning to default for FX
Table B-13:Step 2 of Returning to Default Settings for FX
Using GSD File
Setting
Byte
Value
No.
(Hex)
0
00 H
User
parameter
1
00 H
for 32DP-IF
2
DA H
3
07 H
4
09 H
5
04 H
User
parameter
for special
6
09 H
function
7
0A H
block
(FX
8
0B H
9
0C H
10
H94
11
H00
12
H00
-
User
Parameter
Type
See section 6.1.
BFM #30 lower byte
BFM #30 higher byte
Total length of parameter bytes for this
special function block are 9 bytes (byte
No. 4 ~ 12).
Example: number of BFM for data
exchanged every cycle is 4
BFMs (BFM #9 ~ #12).
Specified exchange, ex. BFM #9
Specified exchange, ex. BFM #10
-4AD)
2N
Specified exchange, ex. BFM #11
Specified exchange, ex. BFM #12
Must be returned to "0000 H" in BFM
#20.
BFM #21 lower byte: "00 H"
BFM #21 higher byte: "00 H"
-
-4AD
2N
-4AD
2N
Description
-
Appendix B
Using Programming Tool
Setting
Register
Value
No.
(Hex)
D200
0000 H
D201
07DA H
D202
0409 H
D203
0A09 H
D204
0C0B H
D205
0094 H
D206
0000 H
B-13
Higher/
Lower
Byte
Lower
Higher
Lower
Higher
Lower
Higher
Lower
Higher
Lower
Higher
Lower
Higher
Lower
Higher