FX2N-32DP-IF Profibus-DP Interface Unit
6.

User Parameter

6.1

User Parameter Rules

Some bytes of input data and output data exchanged with the DP-master (the 32DP-IF's con-
figuration) must be defined by user parameter. Also defined by user parameters are how the
exchanged data should be distributed between the available I/O points and special function
blocks. Some applications require initial settings, like gain and offset of analog blocks. For
these purposes, the 32DP-IF requires a set of parameter data, which must be determined by
the user parameter.
For "after power on" parameter, refer appendix A. For user parameter example, refer to appen-
dix B.
Note:
User parameters become valid for 32DP-IF and special function blocks (ex. FX
4DA).
Table 6.1: User Parameter Configuration
User parameter
for 32DP-IF
User parameter
for first special
function block
User parameter
for second special
function block
:
:
*1 m
, m
1
2
Byte No.
0
1
2
:
:
1 + (2 + m
1 + (2 + m
:
:
*1
1 + (2 + m
1
:
:
: Total length of parameter data for this special function block.
*1
)
1
*1
) +1
1
*1
) + (2 +m
)
2
User Parameter 6
-4AD, FX
-
2N
2N
6-1