1.7 BLOWER WIRING

These heaters have a factory installed electrical
junction box, variable speed fan and tempera-
ture sensing remote. These components are
located behind the front. Use of the fan requires
that the junction box (factory installed) be con-
nected to 220/240 VAC service before perma-
nently enclosing the heater. The access hole
for connecting the service wires is found on the
lower exterior side of the appliance. See Figure
33. Figure 35 shows the fan, switches, and fan
wiring diagram.
240V BLOWER
Figure 35. Fan, Switches and Fan Wiring Diagram
24
Note: if any of the original wire as supplied with the appliance
must be replaced, it must be replaced with type 105º C (221° F)
rated wire. Wires must have high temperature insulations.
GROUND TERMINAL TO
FIREPLACE CHASSIS
AUX 300 CE
Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15
NOTE: If the supply cord is damaged, it must be replaced by
the manufacturer, an authorized service agent, or a similarly
qualifi ed person in order to avoid a hazard.