Electrical; Field Wiring (At Install) - Heat & Glo Foundation Bay Series Installation And Operating Manual

Co-linear direct vent gas fireplaces, natural gas
Table of Contents

Advertisement

A. FIELD WIRING (AT INSTALL) See Terminal Details in Section 9B and 9C.
Figure 9A
Cap shown is from the PVK Series
SUPPLY
CAP
VAC
AMPERAGE
PVK-45
120
3.2
PVK-67
120
3.4
PVI-45
120
4.9
PVI-67
120
7.3
To light the fireplace: Activate the switch.
The fireplace has a pre and post timer, set at the factory for 30 seconds.
The powervent will start after switch is activated.
The flame will not turn on for 30-60 seconds after switch is activated.
The powervent will run for 30 seconds after the fireplace has been shut off.
Heat & Glo • FDN-4-BAY, FDN-5-BAY, FDN-6-BAY, FDN-7-BAY Installation Manual • 16400-9802 Rev. P • 4/21

9 - ELECTRICAL

CAP
VAC AMP HP
PVK-45
120
1.2
PVK-67
120
1.4
PVI-45
120
2.9
PVI-67
120
5.3 13/16
Insulation Pad
(Must be cut in center to accomodate
vent size.)
Optional Mechanical Damper
Not included with appliance from factory
#
#
FUNCTION
FUNCTION
1
1
120 VAC SW2 LIGHTS
120 VAC SW2 LIGHTS
2
2
120VAC SW2 LIGHTS
120VAC SW2 LIGHTS
3
3
120VAC SW1 MAIN FLAME
120VAC SW1 MAIN FLAME
4
4
120 VAC SW1 MAIN FLAME
120 VAC SW1 MAIN FLAME
5
5
120 VAC SUPPLY
120 VAC SUPPLY
6
6
NEUTRAL
NEUTRAL
7
7
NEUTRAL POWERVENT
NEUTRAL POWERVENT
8
8
120VAC POWERVENT
120VAC POWERVENT
9
9
24VAC FLUE DAMPER POWER
24VAC FLUE DAMPER POWER
10 24VAC FLUE DAMPER NEUTRAL
10 24VAC FLUE DAMPER NEUTRAL
11 SW3 FLUE DAMPER PROVE
11 SW3 FLUE DAMPER PROVE
12 SW3 DAMPER PROVE
12 SW3 DAMPER PROVE
13 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
13 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
14 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
14 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
1/9
JUNCTION BOX WITH CAPACITOR
1/7
3/7
RED
BLACK
WHITE
WHITE
Junction Box With Capacitor
Note: Appliance requires dedicated
15 Amp (minimum) circuit.
NOTES:
120 VOLT LOOP
120 VOLT LOOP
120 VOLT LOOP
120 VOLT LOOP
CONNECT TO CONSTANT POWER SOURCE
CONNECT TO CONSTANT POWER SOURCE
DO NOT SHARE NEUTRAL
FROM SPEED CONTROL
OPTIONAL
OPTIONAL
OPTIONAL. USE PURPLE AND WHITE, NOT RED
OPTIONAL. USE PURPLE AND WHITE, NOT RED
NOT USED
NOT USED
TO FAN
GREEN
BLACK
BLACK
BLACK
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fdn-4-bayFdn-5-bayFdn-6-bayFdn-7-bay