FLUEING WITH TWO 90° ELBOWS
V (FT.)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
5' MIN. (1.5 m)
V + H + H
Figure 14. Flueing with Two 90° Elbows
V
H
1
Figure 15. Flueing with Two 90° Elbows
14
NATURAL GAS
H + H
(FT.)
1
3' MAX. (914 mm)
6' MAX. (1.83 m)
9' MAX. (2.7 m)
12' MAX. (3.6 m)
15' MAX. (4.5 m)
= 40' MAX. (12.2 m)
1
H + H
= 15' MAX. (4.5 m)
1
H
1
NATURAL GAS
FLUEING WITH TWO 90° ELBOWS
V (FT.)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
12' MAX. (3.6 m)
5' MIN. (1.5 m)
15' MAX. (4.5 m)
V + H + H
= 40' MAX. (12.2 m)
1
H + H
= 15' MAX. (4.5 m)
1
Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15
PROPANE
FLUEING WITH TWO 90° ELBOWS
V (FT.)
1' MIN. (305 mm)
2' MIN. (610 mm)
3' MIN. (914 mm)
4' MIN. (1.22 m)
5' MIN. (1.5 m)
V + H + H
= 40' MAX. (12.2 m)
1
H + H
= 10' MAX. (3.0 m)
1
V
H
H + H
(FT.)
1
V (FT.)
3' MAX. (914 mm)
1' MIN. (305 mm)
6' MAX. (1.83 m)
2' MIN. (610 mm)
9' MAX. (2.7 m)
3' MIN. (914 mm)
4' MIN. (1.22 m)
5' MIN. (1.5 m)
H
H + H
(FT.)
1
2' MAX. (610 mm)
4' MAX. (1.22 m)
6' MAX. (1.83 m)
8' MAX. (2.4 m)
10' MAX. (3.0 m)
PROPANE
FLUEING WITH TWO 90° ELBOWS
H + H
(FT.)
1
2' MAX. (610 mm)
4' MAX. (1.22 m)
6' MAX. (1.83 m)
8' MAX. (2.4 m)
10' MAX. (3.0 m)
V + H + H
= 40' MAX. (12.2 m)
1
H + H
= 10' MAX. (3.0 m)
1