• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15
Owner's Manual
SAI Global
Ref No GSCS20165
AS 4553:2008
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• DO NOT PLACE ARTICLES ON OR AGAINST THIS
APPLIANCE.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
This is a room sealed appliance and no other ventilation is
required than what is provided.
WARNING! DO NOT modify this appliance.
Installation and Operation
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST-HVBI-AUB and is the answer not in the manual?

Questions and answers

Summary of Contents for Heat & Glo ST-HVBI-AUB

  • Page 1 This is a room sealed appliance and no other ventilation is required than what is provided. by a qualifi ed installer, service agency, or the gas supplier. WARNING! DO NOT modify this appliance. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 2 Save this manual for future reference. Heat & Glo, a brand of Hearth & Home Technologies 7571 215 Street West, Lakeville, MN 55044 Copyright 2015 • Printed in U.S.A. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 3: Table Of Contents

    3.3 Parts Replacement ..................41 3.4 Adjustments and Replacement Parts ............41 3.5 Maintenance Tasks ..................42 3.6 Troubleshooting ................... 43 4.0 REPLACEMENT PARTS................... 44 Limited Lifetime Warranty ................... 47 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 4: Installation Instructions

    36-3/16 in. (610m) (121mm) (114mm) (919.3mm) TOP STANDOFFS FLUE FLUE COLLAR COLLAR LOUVER BOTTOM LOUVER GAS CONTROLS & LABELS GAS LINE ELECTRICAL ACCESS ACCESS Figure 1. Diagram of the ST-HVBI-AU Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 5: Locating The Heater

    Metal Sides or Ends ...13 ....1/2 Top ........64 ....2-1/2 Ceiling* ......787 ....31 * The clearance to the ceiling is measured from the top of the unit, excluding the standoffs (see Figures 1 and 2). Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 6: Framing The Heater

    2 in. x 4 in. (51 mm x 102 mm) lumber or heavier. 42-5/8 in. 42-1/2 in. 23.2 in. 35 in. 53-3/4 in. (1.21 m) (1.08 m) (590 mm) (889 mm) (1.37 m)  Figure 3. Framing Dimensions Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 7 LP Gas cylinder. A fl ue terminal is considered to be a source of ignition. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 4 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 8 NOTE: PIPES OVERLAP 32 mm (1-1/4 in.) AT EACH JOINT. Figure 5. DVP-Series Direct Flue Component Specifi cations (127 mm (5 in.) inner pipe / 203 mm (8 in.) outer pipe) Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 9: Exhaust Restrictor Installation

    EXHAUST RESTRICTOR NOTICE: Before painting, contact your dealer for information on the appropriate high temperature paint. Figure 7. Exhaust Restrictor - Air Passage Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 10: Flue System Approvals And Installations

    fl ueing confi guration used. STORM COLLAR VERTICAL TERMINATION ROOF FLASHING HORIZONTAL TERMINATION WALL FIRESTOPS PIPE LENGTH 90º ELBOW TERMINATION KITS CEILING FIRESTOP DVP-TVHW DVP-TRAP2 Figure 8. Flue System Components and Termination Kits Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 11 STRAIGHT UP VERTICAL FLUEING V (FT.) 12.2 M MAX. (40 ft.) TERMINATION CAP Figure 9 STRAIGHT OUT HORIZONTAL FLUEING Max. Run 610 mm (24 in.) Figure 10 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 12 5’ MIN. (1.5 m) 10’ MAX. (3.0 m) V + H = 40’ MAX. (12.2 m) V + H = 40’ MAX. (12.2 m) Figure 12. Flueing with One 90° Elbow Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 13 8’ MAX. (2.4 m) 5’ MIN. (1.5 m) 10’ MAX. (3.0 m) V + V + H = 40’ MAX. (12.2 m) Figure 13. Flueing with Two 90° Elbows Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 14 V + H + H = 40’ MAX. (12.2 m) H + H = 15’ MAX. (4.5 m) H + H = 10’ MAX. (3.0 m) Figure 15. Flueing with Two 90° Elbows Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 15 + H + H = 36’ MAX. (10.9 m) H + H = 12’ MAX. (3.6 m) H + H = 8’ MAX. (2.4 m) Figure 16. Flueing with three 90° elbows Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 16 10’ MAX. (3.0 m) V+ V + H + H = 36’ MAX. (10.9 m) H + H = 10’ MAX. (3.0 m) Figure 17. Flueing with three 90° elbows Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 17 • Overlap pipe slip sections at least 1-1/2 inches (38 mm). • Use pilot holes for screws. • Screws must not exceed one inch long. • Pipe may separate if not properly joined. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 18 For elbows that are changing the fl ue direction, two screws minimum should be put in the outer fl ue at the joint to prevent the elbow from rotating. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 19 12 in . (305 mm) CHIMNEY HOLE Figure 24. 254 mm x 305 mm Hole and Flue Pipe EXISTING CEILING JOISTS FRAMING MEMBERS CEILING Figure 26. Hole & New Framing Members Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 20 Figure 29. Flueing through the Wall RAFTER • The termination kit should pass through the wall fi restops from the exterior of the building. CEILING CEILING FIRESTOP Figure 28. Attic Firestop Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 21 WARNING: FOLLOWING NATIONAL REG- ULATIONS AND CODES OF PRACTICE FOR MINIMUM CLEARANCES FROM GAS TERMINALS, AND PLACEMENT OF GAS TERMINAL. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 22: Connecting The Gas Supply

    MUST be the fi nal connection to the gas heater. 3. ISOLATING SWITCH: Location within 1 metre of fi replace, subject to mantelpiece etc. Check to ensure it remains clear of any mantelpiece instal- lation. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 23: Ignition System Wiring

    CORD 220-240 VAC 8K1 WIRE HARNESS TO OPTIONAL COMPONENTS JUNCTION CORD OPTIONAL ON/OFF WALL SWITCH ORANGE GREEN (PILOT) BLACK (MAIN) BATTERY PACK 6V DC (C X 4) BROWN GROUND Figure 34 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 24: Blower Wiring

    33. Figure 35 shows the fan, switches, and fan wiring diagram. 240V BLOWER GROUND TERMINAL TO FIREPLACE CHASSIS JUNCTION CORD AUX 300 CE Figure 35. Fan, Switches and Fan Wiring Diagram Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 25: Mantel Clearances

    1010 INSIDE EDGE OF DRESS GUARD OPENING DRESS GUARD NOTE: ALL DIMENSIONS ARE SHOWN IN MILLIMETERS Figure 37 HIGH TEMP (300 ºF. 150 ºC. MIN.) SEAL JOINT Figure 38 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 26: Log Placement

    LOG #2 (SRV2068-701): Locate log #2 in left front corner of the log grate using bottom grooves for placement. Push log against grate tabs on fi rst and second bars. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 27 Place log #5 on top of fl at spot on log #1 and against the inside of log #2. Be careful not to reposition log #2 when placing this log. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 28: Installation / Removal Of Optional Vanity Panel

    WING NUT VANITY PANEL VANITY PANEL MOUNT MOUNT LOCATION LOCATION BRACKET BRACKET GROUND GROUND WIRE WIRE Figure 40 Hex Fastener • Reattach front. Figure 39 Wing Nut on Bracket Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 29: Control Module Heat Shield Instruction

    • Remove black sheet metal plate from manual bag. Bend (3) tabs approximately 90 degrees on plate to form shield as shown in Figure 41. Figure 42. Heat Shield Placement Figure 41. Heat Shield Bends Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 30: Installer Testing

    Burner Injector #30 (3.26 mm) #49 (1.85 mm) An in-line regulator MUST be installed if the gas pressure exceed 3.40 kPa. Failure to install a regulator could damage valve. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 31: Operation Cautions

    • Do not spray aerosols in the vicinity of this appliance while it is in operation. NOTE: THE TIPS OF THE FLAMES SHOULD NEVER HIT THE TOP OF THE FIREBOX. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 32: For Your Safety

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 33: Control Module Operation

    REMOTE or ON. If the ignition command again fails, the module will emit an LED error code, prior to going back into LOCK- OUT mode. Contact your dealer for service if this occurs. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 34: Remote Control Operation

    The RC300AU is approved for interior installation and • Drywall Anchor (2) should not be used in exterior applications. • Screws (2) • Keep remote control out of reach of children. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 35 Figure 48. Remote in Housing Figure 46. Temperature Scale 5. Close the housing door. See Figure 49. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 36 3 min. ON, 12 min. OFF FAN CORD FAN CORD AUX 300 AUX 300 MODULE MODULE LEARN BUTTON Figure 52. Programming RC300AU Figure 51. Plug Fan into AUX300CE Module Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 37 Use the SELECT button to select the current Select feature. Use the UP and DOWN arrows to toggle through the menu functions and value selec- tions in the submenus. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 38 HEIGHT setting and will automatically adjust after 10 is off. When the fi replace is turned back ON, the AUX1 seconds. and AUX2 settings will be restored to the previous setting. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 39 NOTICE: No functions will be usable until child lock feature • Locate house circuit breaker for fi replace. is disabled. • Turn off the circuit breaker. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 40: Servicing And Maintenance

    HOT. 7. Visually inspect the fl exible power supply cord; if damaged, contact the service agent for a special replacement cord assembly. Figure 54 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 41: Removal Of Covers For Servicing

    A wiring diagram for the appliance is shown in SECTION 2.0 OPERATING INSTRUCTIONS. A replacement part table is shown in SECTION 4.0 of this manual. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 42: Maintenance Tasks

    4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and fl ashing remains intact. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 43: Troubleshooting

    fl ame sensing rod. Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 44: Replacement Parts

    Qty 2 req 2083-070 Burner Assembly N SRV2082-014 Burner Assembly P SRV2082-015 Vanity Panel 2078-182 Lower Door 2082-042 Dress Guard 2068-040 Additional service part numbers appear on following page. 4/15 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 45: Service Parts

    14.18 Valve Bracket 2118-104A **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 500mA~10A 3/4” long Additional service part numbers appear on following page. Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 46 RC300 AU Remote REM300-HNG-AU Component Bag 2166-036 Touch-Up Paint TUP-GBK-12 Conversion Kits Propane to Natural P2N-STHVBI-AUB Natural to Propane N2P-STHVBI-AUB Pilot Ori ce N (.020) 2098-520 Pilot Ori ce P(.0121) 2098-512 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 47: Limited Lifetime Warranty

    All Parts and Material Except 1 Year as covered by Conditions, Exclusion, and Limitations listed Igniters, Electronic Components, and Glass 2 years Factory-installed blowers Molded refractory panels 3 years Firepots and burnpots Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 48 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 49 However, if you Melbourne Perth Sydney Fireplace Corner 444 Swan Street 277 Lord Street Richmond 3121 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...
  • Page 50 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2015 Heat & Glo • ST-HVBI-AUB • 2082-980 Rev. Q • 5/15...