Accel lever is fully closed when the
remote control cables have been
connected.
● The advancer arm on the engine should
have contact with the stopper of the
carburetor throttle valve to enable it to
be fully closed.
Advancer arm
5 Adjust cable joint until the hole
meets with the Advancer Arm
pin. After adjustment lock a cable
joint with a nut and secure with
R-shaped pin.
R shaped pin
Nut
Stopper
(Throttle fully
closed side)
Throttle
Cable
Cable Joint
Connecting Cords and cable
1 Connect cable harness B to cable
harness A.
2 Connect pink and light blue leads
from cable harness A and B to each
other.
Cable
Harness A
�������
!
Do not disconnect the electric
couplers while the engine is running,
as this will damage the C.D. unit and
could result in a serious electric shock.
25
INSTALLATION
Lead wire
Cable
Harness B
3