Please note that in the A-REC DURATION set-
ting, MAN cannot be selected when the MOTION DE-
TECTION setting in the <INITIAL SET UP> menu is
"ON".
13. Turn the SHUTTLE ring to the left or press the SET UP
button.
INFORMATION
eration" on page 53 for details of the alarm recording.

Camera Alarm Rec setting

This is the setting for the camera to start recording when
ALARM IN terminal is grounded (alarm recording signal is
input). This setting is only effective during alarm recording.
After alarm recording, operations return to their prior settings.
Example: Setting the RECORD ALARM to "ALL" (the de-
fault setting is "SEP").
1. Press the SET UP button to display the <MENU SETTING>
menu.
2. Turn the JOG dial to move the cursor to A-REC/M-DET
SETTING then turn the SHUTTLE ring to the right.
• The <A-REC/M-DET SETTING> menu will appear.
3. Turn the JOG dial to move the cursor to RECORD ALARM
then turn the SHUTTLE ring to the right to fix setting.
• The sub-item will start flashing.
4. Turn the JOG dial to display "ALL", and turn the SHUTTLE
ring to the right to fix setting.
• The sub-item will stop flashing.
@RECORD ALARM
item of RECORD ALARM will be changed as follows:
"SEP": The alarm recording will start only with the
camera which received the alarm signal. If several
cameras received alarm input at once, all of those
cameras will start alarm recording.
"ALL": The alarm recording will start with all cameras
set to be operated on the <DEFINE ALARM GROUP>
menu when ALARM IN terminal is grounded.
5. Turn the SHUTTLE ring to the left or press the SET UP
button.
When the RECORD ALARM setting is set to "SEP",
the "PRI" setting on the <DEFINE GROUP SETTING>
menu at this time can only be either " 1 " or " - ", and
then the "FILD" will not be appear on screen.

Pre-alarm recording setting

During alarm recording, it is possible to record the infor-
mation before the ALARM IN terminal is activated.
Example: Set the PRE A-REC to "LONG" (the default set-
ting is "OFF").
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
Please refer to "Alarm Recording op-
A-REC DURATION
15S
ALL
PRE A-REC
OFF
By turning the JOG dial, the sub -
SEP
ALL
1. Make settings for IMAGE QUALITY , MAX REC FIELDS ,
DEFINE GROUP SETTING, A-REC DURATION and RECORD
ALARM as shown on page 35 - 37 .
A-REC DURATION
@RECORD ALARM
PRE A-REC
2. Turn the JOG dial to move the cursor to PRE A-REC and
turn the SHUTTLE ring to the right to flash the sub-item.
A-REC DURATION
RECORD ALARM
@PRE A-REC
3. Turn the JOG dial to flash LONG, and turn the SHUTTLE
ring to the right. The unit will be in stand-by mode for the
Pre-alarm recording.
• PRE ALARM REC indicator on the front of the unit will start
illuminating.
A-REC DURATION
RECORD ALARM
@PRE A-REC
By turning the JOG dial, the sub-
item of PRE A-REC will be changed as follows:
OFF
LONG
4. Ground the ALARM IN terminal.
• The unit will start alarm recording.
The duration of recording before the ALARM IN ter-
minal is triggered depends on the MAX REC FIELDS,
IMAGE QUALITY, and PRE A-REC settings. Please
refer to "Pre-alarm Recording" on page 54 for details.
Setting cannot be altered in either the NORMAL
REC SETTING menu or the A-REC/M-DET SET-
TING menu when the PRE A-REC menu is set to
SHORT, MEDIUM, or LONG. In addition, the SE-
LECT REC MODE (in the <NORMAL REC SET-
TING> menu) will display A-REC.
INFORMATION
To activate pre-alarm recording on
Timer programmes, please refer to "Pre-alarm Re-
cording" on page 54.
Following the end of Pre-alarm recording, the regular value
of the Alarm Recording settings returns to the value set in
the IMAGE QUALITY, MAX REC FIELDS, DEFINE GROUP
SETTING, and A-REC DURATION settings.
Alarm input
(ALARM IN signal)
R e c o r d in g
P r e - a l a r m
M o d e
r e c ordi ng
LONG/MEDIUM/SHORT of
Effective
PRE A-REC
recording
IMAGE QUALITY/
setting
MAX REC FIELDS of A-REC
All the CAMERA CH
Effective
set in PRIORITY settings
recording
1 – 5 of the DEFINE
CAMERA CH
ALARM GROUP setting.
setting
When you wish to use the ALARM IN signal to activate Alarm Recording,
CAMERA CH of the cameras to be used must be set to something other than "—".
5M
ALL
OFF
5M
ALL
OFF
5M
ALL
LONG
SHORT
MEDIUM
A l ar m
r ec o rd i ng
IMAGE QUALITY/
MAX REC FIELDS/
A-REC DURATION
When RECORD ALARM setting is SEP,
only the CAMERA CH receiving an
Alarm Recording signal.
When RECORD ALARM setting is ALL,
all the CAMERA CH specified in the
DEFINE GROUP SETTING setting.
37