Setting The Maximum Recording Fields; Selecting The Recording Mode Of The Cameras - Mitsubishi DX-TL1600EM Installation And Operation Manual

Mitsubishi dvr installation and operation manual dx-tl1600em
Hide thumbs Also See for DX-TL1600EM:
Table of Contents

Advertisement

3. Turn the JOG dial to move the cursor (
REC SETTING then turn the SHUTTLE ring to the right.
• The <NORMAL REC SETTING> menu appears.
<NORMAL REC SETTING>
@IMAGE QUALITY
4. Check that the cursor is next to the IMAGE QUALITY and
turn the SHUTTLE ring to the right.
• The sub-item of IMAGE QUALITY will start flashing.
<NORMAL REC SETTING>
@IMAGE QUALITY
5. Display STANDARD by turning the JOG dial then turn the
SHUTTLE ring to the right.
• The flashing will stop. Now the setting has been completed.
<NORMAL REC SETTING>
@IMAGE QUALITY
age quality setting will be changed as below :
HIGH

Setting the maximum recording fields

Example: Setting the maximum recording fields to "6.25F"
(the default setting is "12.5F").
1. After step 5 of IMAGE QUALITY setting procedures above,
turn the JOG dial and move the cursor to "MAX REC FIELDS".
<NORMAL REC SETTING>
@MAX REC FIELDS
2. Turn the SHUTTLE ring to the right to flash the sub-item.
<NORMAL REC SETTING>
@MAX REC FIELDS
3. Turn the JOG dial to display "6.25F" then turn the SHUTTLE
ring to the right.
• The "6.25F" is now selected.
<NORMAL REC SETTING>
@MAX REC FIELDS
mum recording fields setting will be changed as
below:
25F
1F
The underlined items cannot be selected when
the MOTION DETECTION setting is active.
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Basic Operations
HIGH
MAX REC FIELDS
12.5F
SELECT REC MODE
(A)
DEFINE GROUP SETTING
HIGH
MAX REC FIELDS
12.5F
SELECT REC MODE
(A)
DEFINE GROUP SETTING
STANDARD
MAX REC FIELDS
12.5F
SELECT REC MODE
(A)
DEFINE GROUP SETTING
By turning the JOG dial, the im-
SUPERIOR
BASIC
MEDIUM
STANDARD
IMAGE QUALITY
STANDARD
12.5F
SELECT REC MODE
(A)
DEFINE GROUP SETTING
IMAGE QUALITY
STANDARD
12.5F
SELECT REC MODE
(A)
DEFINE GROUP SETTING
IMAGE QUALITY
STANDARD
6.25F
SELECT REC MODE
(A)
DEFINE GROUP SETTING
By turning the JOG dial, the maxi-
12.5F
8.33F
6.25F
2.5F
4.17F
5F
) to NORMAL
When MOTION DETECTION setting in the INI-
TIAL SET UP menu is turned ON, the MAX REC
FIELDS for each time setting will be automatically
altered as follows. These settings will not automati-
cally revert to their former values even if MOTION
DETECTION is turned OFF.
Case of <NORMAL REC SETTING> menu and <A-
REC/M-DET SETTING> menu.
"25F" } "12.5F", "8.33F" } "6.25F" , "5F" } "4.17F"
Case of "MODE" in the <TIMER PROGRAM> menu.
"25" } "12.5", "8.33" } "6.25" , "5" } "4.17"
The setting you are making here is only for the nor-
mal recording, NOT for the timer recording or alarm
recording. You need to make the timer recording set-
tings on the <TIMER PROGRAM> menu. And you need
to make the alarm recording setting on the <A-REC/
M-DET SETTING> menu. For details please refer to
"Various recording settings" on page 35.
The settings made for IMAGE QUALITY and MAX
REC FIELDS are shared with A, B, and C of SE-
LECT REC MODE.
Press the SET UP button to exit settings.
4. Check the estimated recording time.
• After setting the image quality the <ESTD TIME> will be
displayed. By changing recording settings, <ESTD TIME>
will change its length of time (Alarm recording setting does
not affect this setting).
The available recording time will be changed de-
pending on the setting of the image quality and the
max recording fields. This estimated recording time
display will include all HDD including external devices.
For available recording time, please refer to "Record-
ing time table" on pages 81.

Selecting the recording mode of the cameras

There are 3 types of the recording mode : A, B and C.
This setting is to choose the SELECT REC MODE on the
<NORMAL REC SETTING> menu.
Example: Choose SELECT REC MODE (B) (the default
setting is (A)).
1. After step 3 of MAX REC FIELDS setting procedures above,
turn the JOG dial and move the cursor to "SELECT REC MODE".
<NORMAL REC SETTING>
IMAGE QUALITY
STANDARD
@MAX REC FIELDS
6.25F
SELECT REC MODE
(A)
DEFINE GROUP SETTING
<ESTD TIME>
1D12H11M
<NORMAL REC SETTING>
IMAGE QUALITY
STANDARD
MAX REC FIELDS
6.25F
@SELECT REC MODE
(A)
DEFINE GROUP SETTING
13