If you suspect that your ROKSAN K3 Integrated Amplifier is not operating
properly, you should check all the connections carefully. Pay particular
attention to speaker phasing and channel connections. Phono plugs should
be fully inserted - a frequent cause of problems is due to the phono plug
surrounds not making proper contact. On the next page are some
commonly encountered problems with suggestions for possible cures. The
list is not exhaustive: If you have any unresolved problems, please consult
ROKSAN or your appointed ROKSAN dealer or distributor.
!
SYMPTOM
LIKELY CAUSE
AC Mains lead not
No power
inserted properly Unit
not switched on
Amplifier in STAND BY
mode (MODE light
GREEN)
No output on
Missing or bad input
one or both
signal connection
channels
Incorrect speaker
connection
Very low sound
output
Wrong input selected
Tape Monitor selected
Poor speaker
imaging, lack
Amplifier set in 20dB
MUTE position (MODE
of Bass output
light AMBER)
Loudspeakers
connected out of phase
Hum from
Incorrect grounding
speakers
Page 14
!
!

Troubleshooting

!
Roksan Audio Ltd
CLASSIFICATION: General Use
All specifications are liable to change without notice. E&OE
SUGGESTED REMEDY
Ensure AC Mains lead is fully
inserted Switch unit on (on the
front underside)
Press MODE button to set
amplifier in operational mode
(MODE light RED)
Check all input connections

Check speaker output
connections on rear panel
Select correct input, ascertain
source is working
Deselect Tape Monitor
Press MODE button to set
amplifier in operational mode
(MODE light RED - check
volume setting first)
Check polarity of speaker
connections (especially
important if Multi-wiring, Multi-
amping)
Check Mains polarity and
grounding on all connected
equipment