Troubleshooting - Roksan Audio Caspian User Manual

Hide thumbs Also See for Caspian:
Table of Contents

Advertisement

KNOW YOUR CASPIAN
When you first power up from the Mains Switch on the rear panel, the amplifier runs a self-test during which
all the Indicators pulse twice. When the self-test is complete the amplifier goes into Standby and the MODE
Indicator glows RED.
During Standby, the power stage of the amplifier shuts down to reduce power consumption and heat.
If the amplifier detects an external fault, such as a short-circuit on the loudspeaker leads, the MODE Indicator
light will flash from YELLOW to AMBER, and the power amplifier stage will shut down. The amplifier will wait
for a few seconds and 'try again'. If the fault persists, the amplifier will revert to Standby.
If the amplifier overheats through overload or lack of ventilation, the Caspian will revert to Standby until it has
cooled down. If it subsequently overheats the amplifier will revert to Standby and stays in Standby. You will
then have to wait until the amplifier cools down fully and will have to bring it out of Standby manually.
In the unlikely event of an internal fault such as a power supply failure, the MODE Indicator light will flash RED
and the amplifier will shut down. The amplifier will then run a self-test. If all is well, the amplifier will revert to
Standby. If the fault persists, the Indicator light will continue to flash.
T R O U B L E S H O O T I N G
If you suspect that your ROKSAN Caspian Integrated Amplifier is not operating properly, you should check all the
connections carefully. Pay particular attention to speaker phasing and channel connections. Phono plugs should
be fully inserted- a frequent cause of problems is that Phono plug surrounds do not make proper contact. Below
are some commonly encountered problems with suggestions for possible cure. The list is not exhaustive: If you
have any unresolved problems, please consult your appointed ROKSAN dealer or distributor.
SYMPTOM
No power
No output on one or both
channels
Very low sound output
Poor speaker imaging, lack
of Bass output
Hum from speakers
Roksan Audio ltd
CLASSIFICATION: General Use
All specifications are liable to change without notice. E&OE
LIKELY CAUSE
AC Mains lead not inserted properly
Unit not switched on at rear panel
Amplifier in stand-by mode (MODE light
RED)
Missing or bad input signal connection
Incorrect speaker connection
Wrong input selected
Tape Monitor selected
Over heating
Amplifier set in MUTE position
Loudspeakers connected out of phase
Incorrect Grounding
Page 9 of 11
C a s p i a n Integrated Amplifier
SUGGESTED REMEDY
Ensure AC Mains lead is fully inserted
Switch unit on at rear panel
Press MODE button to set amplifier in
operational mode (MODE light
GREEN)
Check all input connections
Check speaker output connections on
rear panel
Select correct input, ascertain source is
working
Deselect Tape Monitor
Allow amplifier to cool, increase
ventillation or use at lower volume
Deselect MUTE (check volume setting
first)
Check polarity of speaker connections
(especially important if Multi-wiring,
Multi-Amping)
Check Mains polarity and grounding on
all connected equipment