If you suspect that your ROKSAN Caspian Integrated Amplifier is not operating properly, you
should check all the connections carefully. Pay particular attention to speaker phasing and chan-
nel connections. Phono plugs should be fully inserted- a frequent cause of problems is that Phono
plug surrounds do not make proper contact. Below are some commonly encountered problems
with suggestions for possible cure. The list is not exhaustive: If you have any unresolved prob-
lems, please consult your appointed ROKSAN dealer or distributor.
SYMPTOM
• No power
• No output on one or
both channels
• Very low sound output
• Poor speaker imaging,
lack of Bass output
• Hum from speakers

TROUBLESHOOTING

LIKELY CAUSE
• AC Mains lead not inserted
properly
• Unit not switched on
• Amplifier in shutdown
mode (mode LED is green)
• Missing or bad input
signal connection Incorrect
speaker connection
• Wrong input selected
• Loudspeakers connected
out of phase
• Amplifier muted or volume
set to minimum
• Incorrect grounding
ROKSAN AUDIO
Monitor Audio Ltd, 24 Brook Road, Rayleigh, Essex, SS6 7XJ, United Kingdom
website: www.roksan.co.uk email: info@roksan.co.uk
Tel: +44 (0)1268 740580
Caspian Integrated Amplifier
SUGGESTED REMEDY
• Ensure AC Mains lead is
fully inserted
• Switch unit on (on the front
underside)
• Check all input
connections
• Check speaker output
connections on rear panel
• Select correct input,
ascertain source is working
• Check polarity of speaker
connections (especially
important if Multi-wiring,
Multiamping)
• Check Mains polarity and
grounding on all connect-
ed equipment
Manual